IEC 61724-1 & IEC 61400-12-1 Compliant Framework

Intelligent Renewable Energy Asset Intelligence & Management

An open, research-grade, production-ready framework integrating edge IoT telemetry, 7-dimension asset health assessment (AHI), Explainable AI (SHAP), closed-loop adaptive control, and cryptographic SHA-256 governance across Solar PV, Wind, BESS, and Hybrid power plants.

Zero Dark SCADA Override
Row Level Security (RLS)
HMAC-SHA256 Signed
1 Hz TELEMETRY STREAM
Live Global Fleet Telemetry
Live Stream
Contracted Capacity
300.0 MW
Active: 226.4 MW
Fleet Health (AHI)
98.6 / 100
7-Dimension index
Connected Assets
12 assets
Solar, Wind, BESS
Enterprise Tenants
3
Isolated Partitions
Cryptographic Trust SHA-256 Ledger
All operational adjustments and HITL approvals are hashed into an immutable block sequence.
Architectural Innovations

Why Renewable Asset Operators Choose REGENOVA

Engineered to replace rigid, proprietary SCADA silos with a reusable, scientifically validated intelligence framework.

Multi-Technology Dynamic Dispatch

Unifies Solar PV (IEC 61724-1 irradiance yield and IGBT thermal models), Wind Turbines (IEC 61400-12-1 barometric air density normalisation), Utility BESS (electrochemical setpoint tracking), and Co-located Hybrid POI arbitration under a single interface.

7-Dimension Asset Health Index (AHI)

Continuous multi-criteria health scoring combining thermal degradation (Arrhenius ageing), electrical efficiency, mechanical stress, communication uptime, and environmental stress with transparent factor attribution.

4-Level Explainable AI (SHAP)

Hierarchical anomaly detection: Level 1 physical thresholding, Level 2 CUSUM/EWMA statistical drift, Level 3 Isolation Forest multivariate modelling, and Level 4 physical residual comparison with verified 95.96% precision and 100% recall.

Closed-Loop Adaptive Intelligence

Dynamic climate-adjusted warning thresholds that adapt to seasonal heatwaves while preserving hard emergency trip limits. Built-in 10% HITL guardrail blocks any shift exceeding ±10% without Chief Engineer authorisation.

Multi-Tenancy & Partition Isolation

Enterprise partition isolation enforced across PostgreSQL 18.6 Row Level Security (RLS) and memory layers. Operators and assets from Helios, Aurora, and Solaria are strictly separated with zero cross-tenant leakage.

Cryptographic Trust & Governance

Every telemetry observation, operator override, parameter adaptation, and maintenance dispatch is sealed into a SHA-256 block hash chain with genesis-to-tip validation for regulatory audit readiness.

Heterogeneous Support

Multi-Technology Generation Reference Pipelines

IEC 61724-1 • IEC 61400-12-1 • IEEE 1547-2018
Photovoltaic Generation

IEC 61724-1 Standardised Photovoltaic Modelling

Models DC-to-AC conversion efficiency, thermal clipping derating, and pyranometer plane-of-array (POA) irradiance response.

  • Thermal Clipping: Derates power output above 50.0 °C heatsink temperature.
  • Arrhenius Ageing: Tracks thermal activation energy ($E_a = 0.45\text{ eV}$) across IGBT modules.
  • Soiling Baseline Adaptation: Rolling 14-day exponential smoothing with automatic cleaning advisory.
// IEC 61724-1 Physical Power Model
P_expected = P_rated × (G_poa / 1000) × [1 + γ × (T_cell - 25)]
// Arrhenius Reaction Derating
k(T) = A × exp(-E_a / (k_B × T_kelvin))
// Verified Test Residual Threshold: ±5.0%
Aerodynamic Energy

IEC 61400-12-1 Power Curve Normalisation

Normalises site-specific barometric air density against standard atmosphere ($\rho_0 = 1.225\text{ kg/m}^3$) with gearbox bearing thermal tracking.

  • Density Correction: Continuous normalisation using barometric pressure and nacelle ambient temperature.
  • Gearbox Vibration Monitoring: Detects bearing misalignment and lubrication breakdown.
  • Yaw Misalignment Tracking: Identifies cosine aerodynamic capture losses.
// IEC 61400-12-1 Air Density Normalisation
v_norm = v_measured × (ρ_site / 1.225)^(1/3)
// Barometric Density Formulation
ρ_site = P_barometric / (R_specific × T_kelvin)
// Pitch Angle & Cut-Out Safety Envelope: 25.0 m/s
Electrochemical Storage

Utility BESS Enclosure & Cycle Degradation

Models charge/discharge setpoints, state-of-charge boundaries (5% ≤ SoC ≤ 95%), and active thermal throttling.

  • Round-Trip Efficiency: Tracks coulombic efficiency losses across lithium iron phosphate racks.
  • BMS Thermal Throttling: Initiates operational derating if cell temperatures exceed 40.0 °C.
  • Peak Shaving Integration: Automatic discharge orchestration during high PPA revenue events.
// Electrochemical Boundaries
5.0% ≤ SoC(t) ≤ 95.0% (Cell Protection Window)
// State of Charge Integration
SoC(t) = SoC(0) + ∫ [ η_c × I(t) / C_rated ] dt
// C-Rate Maximum: 1.0C Charge / 1.5C Discharge
Co-located Plant

Co-located Hybrid Power Plant Arbitration

Dynamic arbitration orchestrating Solar PV, Wind Turbine, and BESS capacity behind a shared Point of Interconnection (POI).

  • Curtailment Segregation: Distinguishes utility curtailment commands from physical asset failures.
  • BESS Ramp Smoothing: Absorbs wind gusts and cloud shadow transients to maintain grid compliance.
  • IEEE 1547 Interconnection: Automated voltage ride-through and frequency stabilisation.
// Interconnection Point Arbitration
P_poi(t) = P_solar(t) + P_wind(t) ± P_bess(t) ≤ P_interconnection_limit
// Ramp Rate Regulation
|dP_poi / dt| ≤ R_grid_code (Max 10% rated / min)
// Curtailment Reason Tag: UTILITY_CURTAILMENT
Autonomous Intelligence

The 8-Stage Closed Feedback Loop

From high-frequency sensor ingestion to Human-in-the-Loop decision verification with verified state persistence.

Stage 1
Observe
1 Hz Telemetry
Stage 2
Validate
DQ Checks
Stage 3
Assess
7-Dim AHI
Stage 4
Detect
4-Level AI
Stage 5
Predict
RUL Horizon
Stage 6
Decide
HITL Guardrail
Stage 7
Act
Adapt Baselines
Stage 8
Observe Again
SHA-256 Seal
Enterprise Onboarding

Pre-Enrol Your Generation Portfolio

Register your renewable energy enterprise, utility cooperative, or independent power plant (IPP) into REGENOVA's multi-tenant framework.

Dedicated Tenant Partition
Complete Row Level Security (RLS) isolation. Zero cross-tenant data leakage guaranteed.
Instant HMAC-SHA256 Token Issuance
Receive cryptographically signed credentials for edge sensors and operator accounts.
Immediate PostgreSQL 18.6 Persistence
Records synchronise to the canonical enterprise schema in real time.
Organisation Pre-Enrolment Application
Complete this form to instantiate your utility partition immediately.
Unique prefix for your enterprise partition
Instant Provisioning